Black BLK-SY10 Series Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
64
Dimensions with 2-Way Valve
A
B
C
D
B
H
C
BF2WUDIM_A
BF2WUDIM
AF
A
ctuators,
M
u
l
t
i
-
F
unct
i
on
T
ec
h
no
l
o
gy
M
o
del
s
AFX24-MFT-X1
AFX24-MFT-S-X1 w
/
built-in Aux. Switche
s
2
*
AFX24
-
MFT
-
X1
2*AFX24-MFT-
S
-X
1
D
imensions
(
Inches
)
Fail Safe (psi)
i)
V
alve
S
iz
e
A
B
C
D
(
Max
)
BH
C
AF
2
*AF
F
650HD 2
1.65
9
.00 9.00 19.50
4
.75
2
0
0
F
650HD
U
2
1.65
9
.00 9.00 19.50
4
.75 5
0
F665
HD 2½” 1.7
6
9
.
00
9
.
00
2
0
.
00
5
.
50
2
00
F
665HD
U
2½” 1.7
6
9
.
00
9
.
00
2
0
.
00
5
.
50
50
F
680HD
3”
1.78
9
.00 9.00 20.50
6
.00 50
0
F
680HDU
3”
1.78
9
.00 9.00 20.50
6
.00 5
0
F
6100HD
U
4”
2.05
9
.00 9.00 21.00 7.50 5
0
F
6125HD
U
5
2.14
9
.00 9.00 22.00
8
.50 5
0
F
650-150
S
HP 2
1.75
9
.00 9.00 19.50
4
.75 15
0
F
665-150
S
HP
2½”
1
.
88
9
.
00
9
.
00
20
.
00
5
.5
0
1
5
0
F
680-150
S
HP
3”
1
.
92
9
.
00
9
.
00
20
.
50
6
.
00
150
F
6100-150SHP
4”
2.13
9
.00 9.00 21.00 7.50 15
0
F
650-300
S
HP 2
1.75
9
.00 9.00 19.50
5
.00 15
0
F
665-300
S
HP 2½” 1.88
9
.00 9.00 20.00
5
.88 15
0
F
680-300
S
HP
3”
1
.
92
9
.
00
9
.
00
20
.5
0
6
.
63
1
5
0
F
6100-300
S
H
P
4”
2.13
9
.00 9.00 21.00 7.88 15
0
F
650VI
C
2
3.21 8.60 8.60 18.25
-
20
0
F
665VI
C
2½” 3.77 8.60 8.60 18.70
-
20
0
F
680VI
C
3”
3
.77
8
.
60
8
.
60
1
8
.7
0
-
50
Dimensions with 3-Way Valve
10
10
D
AB
C
D
imensions
(
Inches
)
Fail Safe
(
psi
)
V
alve Size A B
C
D(Max)
B
HC
AF
2
*AF
F
750HD
2”
4
.50 6.15
6
.15
1
5.50 4.75 20
0
F
750HD
U
2”
4
.50 6.15
6
.15
1
5.50 4.75 5
0
F
765HD
2
½” 5.00 6.76
6
.76
1
6.00 5.50
2
00
F
765HD
U
2
½” 5.00 6.76
6
.76
1
6.00 5.50 5
0
F
780HD
U
3”
5.50 7.28
7
.28
1
6.25 6.00 5
0
F
750VI
C
2”
4
.
50
6
.
85
6
.
85
15
.
00
-
50
F
750VI
C
2”
4
.
50
6
.
85
6
.
85
15
.
00
-
200
F
765VI
C
2
½” 5.00 7.46
7
.46
1
5.00
-
5
0
HS
DW
G
P11
Technical Data
Power supply 24 VAC, +/- 20%, 50/60 H
z
24 VDC, +20% / -10
%
Powe
r
runnin
g
7.5
W
consum
p
tio
n
holdin
g
3
W
T
ransformer sizin
g
10 VA
(
Class 2 power source
)
Electrical connectio
n
AFX..
.
3
ft [1m] default, 10 ft [3m] or 16 ft [5m] 18
GA
appliance or plenum cables, with or without 1/2” conduit
connec
t
o
r
-
S
m
o
dels: two
3
f
t [1m] de
f
ault, 10
f
t [3m] or
16 ft
[
5m
]
appliance cables with or without 1/2" conduit
connec
t
or
s
O
verload protectio
n
e
l
ectron
i
c t
h
roug
h
out 0 to 95° rotat
i
on
Operatin
g
ran
g
e Y
*
2 to 10 VDC, 4 to 20 mA
(
default
)
variable
(
VDC, PWM, floatin
g
point, on/off
)
I
nput
i
mpe
d
anc
e
100
k
Ω for 2 to 10 VD
C
(
0.1 mA
)
5
00
Ω
f
or 4 to 20 mA
1
5
00
Ω for PWM, floatin
g
point and on/off control
F
ee
db
ac
k
output
U*
2 to 10 VD
C
, 0.5 mA ma
x
T
or
q
ue minimum 180 in-lb
(
20 Nm
)
Dir
ec
ti
o
n
of
sprin
g
reversible with cw/ccw mountin
g
rotation
*
mo
t
o
r
reversible with built-in switch
Mechanica
l
angle o
f
rotation
*
95°
(
ad
j
ustable with mechanical end stop, 35° to 95°
)
R
unn
i
ng t
i
me spr
i
ng <20 sec
@
-4°F to 122°F [-20°
C
to 50°
C
];
<60 sec @ -22°F
[
-30° C
]
motor
*
150 seconds
(
de
f
ault
)
, variable
(
70 to 220 seconds
)
A
n
g
le of rotation
a
d
aptat
i
o
n
off
(
default
)
O
v
e
rri
de
co
ntr
o
l
*
m
i
n
p
os
i
t
i
on = 0%
mid. position = 50%
max. pos
i
t
i
on = 100
%
Position indicatio
n
visual indicator
,
0° to 95
°
(
0° is sprin
g
return position
)
M
anua
l
overr
ide
5 mm
h
ex cran
k
(
³⁄
₁₆
"
All
en
)
, supp
li
e
d
Humidit
y
max. 95% RH, non-condensin
g
A
mbient tem
p
eratur
e
-22 to 122° F
(
-30 to 50° C
)
Stora
g
e temperatur
e
-40 to 176° F
(
-40 to 80° C
)
H
ous
i
ng
NEMA
2,
IP
54,
E
nc
l
osure
T
ype
2
H
ous
i
ng mater
i
a
l
z
i
nc coate
d
meta
l
an
d
p
l
ast
i
c cas
i
ng
N
o
i
se
l
eve
l
40dB
(
A
)
motor
@
150 seconds, run time dependen
t
62dB
(
A
)
sprin
g
return
Ag
ency listin
g
s
cULus acc. to UL60730-1A/-2-14
,
CAN/CSA E60730-
1:02,
C
E acc. to 2004
/
108
/
E
C
& 2006
/
95
/
E
C
Q
uality standard I
SO
900
1
S
ervicin
g
maintenance fre
e
W
e
i
g
ht
4.6
lb
s.
(
1.9
k
g
)
, 4.9
lb
s.
(
2
k
g
)
w
i
t
h
sw
i
tc
h
* Variable when configured with MFT option
s
Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3.
Programmed for 70 sec motor run time. At 150 sec motor run time, transformer sizing
is 8.5 VA and power consumption is 6 W running / 3 W holding.
i
AFX24-MFT-S-X1
A
uxiliary switche
s
2 x
S
PDT 3A (0.5A)
@
250 VA
C
, UL approve
d
one set at +10°, one ad
j
ustable 10° to 90
°
O
50904 - 02/12 - Subject to change. © Belimo Aircontrols
(
USA
)
, Inc.
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 41 42

Comentarios a estos manuales

Sin comentarios