36
SECTION 3: SOFTWARE SETUP OPERATING GUIDE
3. Using the joystick [u], select the alarm input type (normally open, NO or normally closed, NC).
4. Using the joystick [u], select the alarm output state (ON / OFF).
5. Set the alarm PRIORITY using the joystick.
6. Set the ACTION (O, Preset, Pattern, Scan, or Tour) and the action NUMBER. The numbered action must be predened.
7. Set the DTIME (alarm action time, 3 ~ 60 s). The default setting is ON.
— TIME OUT (3 ~ 60 s): When an alarm is activated, the alarm output is active for the congured alarm activation time
(DTIME).
— MOMENTARY (ON): When an alarm is activated, the alarm output is active continuously until manually deactivated
(96 + PRESET, or by changing the ALARM SETUP menu).
— To temporarily pause an alarm for 10 seconds, press the ESC key.
8. Press the OPEN key or use joystick to save settings.
9. Press the CLOSE key or use joystick to return to previous menu (back).
NOTE
The camera supports four alarm inputs (AL0 - AL3).
AL3 can be used as a digital input for an external D/N. If congured this way, only AL0 - AL2 can be hardware alarm inputs.